Head Memory related Fatal Errors (4)
Error code
- 031140 NVT check ID read parity error 0
- 031141 NVT check ID read parity error 1
- 031142 NVT check ID read parity error 2
- 031143 NVT check ID read parity error 3
- 031144 NVT check ID read parity error 4
- 031145 NVT check ID read parity error 5
- 031180 NVT nozzle rank read parity error 0
- 031181 NVT nozzle rank read parity error 1
- 031182 NVT nozzle rank read parity error 2
- 031183 NVT nozzle rank read parity error 3
- 031184 NVT nozzle rank read parity error 4
- 031185 NVT nozzle rank read parity error 5
- 031240 NVT nozzle rank mode value read parity error 0
- 031241 NVT nozzle rank mode value read parity error 1
- 031242 NVT nozzle rank mode value read parity error 2
- 031243 NVT nozzle rank mode value read parity error 3
- 031244 NVT nozzle rank mode value read parity error 4
- 031245 NVT nozzle rank mode value read parity error 5
- 031300 NVT mode value rank nozzles count read parity error 0
- 031301 NVT mode value rank nozzles count read parity error 1
- 031302 NVT mode value rank nozzles count read parity error 2
- 031303 NVT mode value rank nozzles count read parity error 3
- 031304 NVT mode value rank nozzles count read parity error 4
- 031305 NVT mode value rank nozzles count read parity error 5
- 031381 Head ID read parity error
Occurrence condition
- The error prevention data when the unit reads each data is incorrect.
- Noise occurred when reading memory information or communication failed.
- The contents written to memory are incorrect.
Assumed cause
- Data failure due to noise
- Head FFC failure / connection failure
- Head Failure
Defect-related parts
- Head FFC
- Head Unit
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Checking the connection of FFC connecting to the Head Unit and Main Board
Does the error go away? |
End | Go to step 2 |
| 2 | Replace the Head Unit
|
End | Go to step 3 |
| 3 | Replace the Main Board
|
End | Contact EPSON Local Service Representatives |