CR Scale Torsion Spring (WF-C579R Series)
- Remove the four screws, then remove the Rear Cover (Back) (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
Assembly / 組み立てAttach the two dowels of the Rear Cover (Back) (A) to the positioning holes on the Housing Left (B) and Housing Right (C).

- Remove the two screws, then remove the Rear Top Cover (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Open the ADF/SCN Unit (A).

- Remove the three screws that secure the Housing Left (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Lift the Housing Left (A) to release the two hooks on the front side of the Housing Left.

- Disengage two hooks on the rear side of the Housing Left (A), and remove the Housing Left (A).

Assembly / 組み立てInsert the eight tabs on the Housing Left (A) to the positioning holes of the Housing Upper (B) and the RIPS Unit (C).

- Disengage the hook, and remove the Maintenance Box Cover (A).

- Open the ADF/SCN Unit (A).

- Remove the four screws that secure the Housing Right (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Lift the Housing Right to release the two hooks on the front side of the Housing Right, then remove the Housing Right.

Assembly / 組み立てInsert the four tabs of the Housing Right (A) to the positioning holes on the Ink Supply Unit.

- Remove the six screws, then remove the Housing Upper (A).
: C.B.P-TITE-SCREW-3x10-F/ZN-3C
- Remove the CR Scale Torsion Spring (B) from the CR Scale (A).

- Remove the CR Scale Torsion Spring (B) from the Main Frame (A).