FB BS+ lock error (Error code: 100075)
Cause
- The driving time of the motor exceeded the set time.
- When rotated in the opposite direction to rotation direction
(There was a sudden load error, and the motor rotated in the opposite direction in reaction to it.) - State in which load of motor exceeds expected load, and motor does not rotate at all
Suspected cause
- Foreign object or jammed paper remaining
- Motor cable disconnected
- ADF/SCN Unit failure
Troubleshooting
| Step | Check and measure | Yes | No |
|---|---|---|---|
| 1 | Check for a foreign object and jammed paper remaining |
Go to step 2 | Remove the paper jam paper and foreign object. |
| 2 | Check the connection state of the ADF/SCN cables |
Go to step 3 | End |
| 3 | Check the connection state of the encoder cable |
Replace the ADF/SCN Unit. |
Reconnect the encoder cable. |