AFTER REPAIR ADJUSTMENT [B80] (PRINT HEAD)
Caution / 注意 |
If “Before Repair Operation” (Print Head) is not performed before Print Head replacement, Ink charge of “After Repair Adjustment” may do not perform correctly. |
- Start service support mode.
- Select “Adjustment Main Unit: MENU” from the service support mode top menu.
Select “Print Head: MENU” - “After Repair Adjustment”.
Check Point / チェックポイントSelect and execute the corresponding adjustment item using either procedure below.
- Selecting by entering the program number
- Select “Input B No.-Main Unit Adjust” from the Adjustment menu.
- Press the [#] button and software number key is displayed on LCD. Enter programnumber “80”.
- Press the [#] button.
- Selecting from menu
- Select “Main Parts Adjust: MENU” from the Adjustment Main Unit menu.
- Select “Print Head: MENU” from the Main Parts Adjust menu.
- Select “After Repair Adjustment” from the Print Head menu.
- The inspections and ink filling are executed in the following sequence.
- Head ID Input
- CR Scale Check
- Nozzle Noise Check
- Head Ink Fill
- After ink filling completes, adjustment is executed in the following order.
- Head angular Adj. Mech
- Head Angular Adj. Soft A
- Head Angular Adj. Soft B
- PTS Acc./Dec. Adjust
- Bi-D Adjust (S)
- Bi-D Band Adjust (S)
- Simple adjustment Band Feed Adjust (S)
- A-B Band Adjust
Perform check pattern printing, check that there is no problem, and end the adjustments for after print head replacement.
Check Point / チェックポイントWhen an NG result appears in the printed diagnostics pattern, a full adjustment not a simple adjustment must be performed.