ADF UNIT AFTER REPAIR ADJUSTMENT [D03]

  1. Start service support mode.
  2. Select “ADF/SCN: MENU” from the service support mode top menu.
  3. Select “Adjustment: MENU” from the ADF/SCN menu.

  4. Select “ADF Unit After Repair Adjustment: MENU” from the Adjustment menu.
  5. The following is performed.

    1. Shading Calibration (Back)
    2. Density Adjustment
    3. ADF Scan Position/ Scaling Calibration (600dpi)
    4. ADF Scaling Calibration (300dpi)
    5. ADF Counter Reset
  6. The adjustment end screen appears. Press the [#] button to return to the menu screen