3rd NIP release sensor failure error (error code: 034018)

Cause
  • Intermediate NIP Release sensor failure or Intermediate Release Solenoid failure.

Suspected cause
  • Intermediate NIP Release sensor failure
  • Intermediate Release Solenoid failure
  • Main Board failure
Troubleshooting
Step Confirmation and action Yes No
1

Check the Intermediate Release Solenoid and Intermediate NIP release sensor
Perform “Individual action check (A32 Nip Release Solenoid / Sensor)”. Did you hear of the solenoid operation sound?

Go to step 2

Replace the Intermediate release solenoid.

2 Check the Intermediate Release Solenoid and Intermediate NIP release sensor
Perform “Individual action check (A32 Nip Release Solenoid / Sensor). Is the check result is not good?

Replace the Intermediate NIP Release sensor. (If the trouble is not resolved, replace the main board)

End