CRCM Blowout Error (Error code: 033001)
Cause
CRCM blowout
Suspected cause
- CRCM FFC inserted slanted
- CRCM FFC failure
- Main Board failure
- Power Supply Board Failure
Troubleshooting
| Step | Confirmation and action | Yes | No |
|---|---|---|---|
| 1 | Check the CRCM FFC connection state |
Go to step 2 |
When inserted slantly |
| 2 | Check the CRCM FFC connection state Check the CRCM FFC state to make sure that the FFC is not damaged. (CRCM FFC connection part has come off, FFC disconnected, etc.) |
Replace the main board If not improved, replace the Power Supply Board. |
Replace the CRCM FFC |