CRCM Blowout Error (Error code: 033001)

Cause

CRCM blowout

Suspected cause
  • CRCM FFC inserted slanted
  • CRCM FFC failure
  • Main Board failure
  • Power Supply Board Failure
Troubleshooting
Step Confirmation and action Yes No
1

Check the CRCM FFC connection state
Check that the CRCM FFC is not inserted slanted.

Go to step 2

When inserted slantly
Reconnect the CRCM FFC.

2 Check the CRCM FFC connection state

Check the CRCM FFC state to make sure that the FFC is not damaged.
(CRCM FFC connection part has come off, FFC disconnected, etc.)

Replace the main board

If not improved, replace the Power Supply Board.

Replace the CRCM FFC