PF Belt Tension Stopper
- Remove the three screws, then remove the Left Housing Assy (A) toward the rear of the product.

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Mark (C) the location where the PF Belt Tension Stopper (A) and the PF Pulley Holder (B) touch.

- Loosen the screw that secures the PF Belt Tension Stopper (A).

: C.B.S-TITE-P4-SCREW-3x8-F.ZN-3C
- Remove the PF Belt Tension Stopper (A) feet (B) from the hole in the frame.

- Release the hook by rotating the PF Belt Tension Stopper (B) in the direction of the arrow around the shaft (A), and remove the PF Belt Tension Stopper (B).