SCN UNIT AFTER REPAIR ADJUSTMENT [D04]
- Start service support mode.
- Select “ADF/SCN: MENU” from the service support mode top menu.
Select “Adjustment: MENU” from the ADF/SCN menu.
- Select “SCN Unit After Repair Adjustment: MENU” from the Adjustment menu.
The following is performed.
- Shading Calibration (Back)
- Density Adjustment
- ADF Scan Position/ Scaling Calibration (600dpi)
- ADF Scaling Calibration (300dpi)
- The adjustment end screen appears. Press the [#] button to return to the menu screen