CR Scale
Adjustment / 調整 |
When replacing/removing this part, refer to the following pages and make sure to perform the specified operations including the required adjustments. |
- Remove the two screws.

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Disengage the two hooks by sliding the Right SC Cover (A) toward the rear of the product, then remove it.

- Remove the screw.

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Slide the Left SC Cover (A) toward the rear of the product to disengage the tab.

- Disengage the three tabs by inserting a flathead screwdriver into the gap between the Left SC Cover (A) and the ADF Unit (B), and then remove the Left SC Cover (A).

- Open the Duplex Print Cover (A).

- Remove the two screws, then remove the Connector Cover (A).

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Remove the two screws, then remove the Right Housing Assy (A) toward the rear of the product.

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Remove the two screws.
: C.C.S-TITE-3x6-F.ZN-3C
- Raise the ADF Stopper (A) to lock the ADF Unit.

- Secure the ADF Stopper with one of the screws you removed at step 1.
: C.C.S-TITE-3x6-F.ZN-3C
- Hold the ADF/SCN Unit (A) with both hands as shown above, and open the ADF/SCN Unit (A).

- Open the ADF/SCN Unit (A) and extend the support stand (B) as far as it goes, then support theADF/SCN Unit (A) with the support stand.

Caution / 注意Make sure that the extended support stand is fixed with the two hooks, and the two triangle marks face to each other.

Check Point / チェックポイントWhen closing the ADF/SCN Unit, hold down the switch on the support stand and raise the ADF/SCN Unit in the direction of the arrow to disengage the two hooks, then fold the support stand.

- Remove the three screws, then remove the Left Housing Assy (A) toward the rear of the product.

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Remove the Stacker Assy (A).

- Remove the Cassette Assy (A).

- Open the Front Cover Assy (A).

- While pressing the two hooks of the hinge (A), remove the Front Cover Assy (A) frontward.

- Remove the three screws fastening the Front Left Housing (A).

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Release the hook and remove the Front Left Housing (A).

- Remove the Front Cover Hinge Left (B) from the Dowel on the Front Inner Housing Left (A).

- Remove the four screws, then remove the Front Inner Housing Center (A) frontward.

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Remove the two screws fastening the Front Inner Housing Left (A).

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Remove the Front Inner Housing Left (C) while releasing the place interfering (A) with the ADF/SCN Unit (A).

- Release the Panel FFC (B) from the two clamps (A).

- Remove the two screws and remove the Power Supply Unit Cover (A).
: C.B.S-TITE-SCREW-3x8-F.ZN-3C
- Release the two cables from the two clamps (A).

- Remove the cables from the connectors (CN2 (with hooks), CN3, CN5) of the Power Supply Unit.

- Remove the Power Supply Unit Cable (B) from the Power Supply Unit (A) while releasing the hook.

- Remove the three screws and remove the Power Supply Unit (A).

: C.B.S-TITE-SCREW-3x8-F.ZN-3C
At the full side, disengage the Extension Spring (A) from the hook of the frame.

Caution / 注意- The CR Scale is made of SUS and very fragile. Therefore, take extreme care when handling one.
- If you disassemble the CR Scale, exchange it for the new CR scale.
- Remove the CR Scale (A) from the hook of frame.

- At the home side, remove the CR Scale (A) from the hook of the frame.

Pull out the CR Scale (B) from the slit of the CR Unit (A).

Assembly / 組み立てFollow the procedure below to install the CR Scale.
- At the full side, hook the CR Scale (A) on the frame.

- Hook the Extension Spring (A) on the frame.

- Route the CR Scale (B) through the slit on the CR unit (A).

- At the home side, hook the CR Scale (A) on the frame.

- Check the hook is inserted all the way.

- At the full side, hook the CR Scale (A) on the frame.