Additional setting state error 2 (error code: 032052)
Cause
Occurs when the condition that the connection terminal seems to be defective connection is detected at the main unit and additional cassette connection section.
Suspected cause
- Additional cassette installation failure
- Foreign object (in connection part)
- Additional cassette connection part failure
- Additional cassette main board failure
Troubleshooting
| Step | Confirmation and action | Yes | No |
|---|---|---|---|
| 1 | Check the Additional Cassette installation state |
Go to step 2 | Reassemble the Additional cassette |
| 2 | Check the foreign material in connection part |
Go to step 3 | Remove the foreign object from connection part. |
| 3 | Check the operation after reinstalling the Connection part of optional cassette |
Replace the additional board unit |
End |