Additional setting state error 2 (error code: 032052)

Cause

Occurs when the condition that the connection terminal seems to be defective connection is detected at the main unit and additional cassette connection section.

Suspected cause
  • Additional cassette installation failure
  • Foreign object (in connection part)
  • Additional cassette connection part failure
  • Additional cassette main board failure
Troubleshooting
Step Confirmation and action Yes No
1

Check the Additional Cassette installation state
Check that the Additional Cassette is properly installed.

Go to step 2

Reassemble the Additional cassette

2

Check the foreign material in connection part
Check that there is no foreign object trapped in the contact point between the main unit and the extension cassette

Go to step 3

Remove the foreign object from connection part.

3

Check the operation after reinstalling the Connection part of optional cassette
Replace the connection part of optional cassette with normal product and check operation.

Replace the additional board unit

End