PF Encoder Board (EM-C800 Series)
Adjustment / 調整 |
When replacing this part, you need to run the menu from the service support mode before replacing it. Refer to the following to execute. |
- Remove the four screws, then remove the Rear Cover (Back) (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
Assembly / 組み立てAttach the two dowels of the Rear Cover (Back) (A) to the positioning holes on the Housing Left (B) and Housing Right (C).

- Remove the two screws, then remove the Rear Top Cover (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Open the ADF/SCN Unit and remove the three screws that secure the Housing Left (A).
: C.B.P-TITE-SCREW-3x10-F.ZN-3C
- Lift the Housing Left (A) to release the two hooks on the front side of the Housing Left.

- Disengage two hooks on the rear side of the Housing Left (A), and remove the Housing Left (A).

Assembly / 組み立てInsert the eight tabs on the Housing Left (A) to the positioning holes of the Housing Upper (B) and the RIPS Unit (C).

- Remove the screw that secures the PF Encoder Board (A).
: C.B.S-TITE SCREW,2X8,F/ZN-3C
- Disconnect the FFC (B) from the connector of the PF Encoder Board (A), and remove the PF Encoder Board (A) avoiding contact with the PF Scale (C).

Assembly / 組み立てAttach the two dowels on the PF Encoder Board (A) to the positioning holes of the frame.

Adjustment / 調整 |
After replacing this part, a specific menu must be executed from the service support mode. Refer to the following to execute. |