MAIN-B connection Error (error code: 100048)
Cause
Occurs if communication is not possible between the ADF/SCN main board and Main Board Assy of the main unit.
Suspected cause
- Faulty connection between ADF/SCN main board and Main Board of the main unit (cable disconnected or broken)
- ADF/SCN Unit failure
- Main Board Assy failure
Troubleshooting
| Step | Check and measure | Yes | No |
|---|---|---|---|
| 1 | Check the connection state of the ADF/SCN cables
Is the result OK? |
Go to step 2 |
|
| 2 | Reinstall and check the ADF/SCN Unit |
Replace the Main Board Assy. |
Replace the ADF/SCN Unit. |