IS load position reverse error (error code: 000113)
Cause
- State in which load of IS motor exceeds expected load
- When rotated in the opposite direction to rotation direction
(There was a sudden load error, and the motor rotated in the opposite direction in reaction to it)
- State in which load of motor exceeds expected load, and motor does not rotate at all
Suspected cause
- Foreign object remaining
- Inksystem gear train part damaged
- IS encoder failure
- IS motor failure
- Main Board Assy failure
Troubleshooting
| Step | Check and measure | Yes | No |
|---|---|---|---|
| 1 | Check the state of the Inksystem gear train parts
Is the result OK? |
Go to step 2 |
|
| 2 | Perform IS motor operation check 1 |
Go to step 3 |
Replace the Inksystem Assy. |
| 3 | Perform IS motor operation check 2 |
Replace the Main Board Assy. |
Replace the Inksystem Assy. |