CR Scale

Adjustment / 調整

When replacing this part, you need to run the menu from the service support mode before replacing it.

  1. Remove the two screws.

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  2. Disengage the two hooks by sliding the Right SC Cover (A) toward the rear of the product, then remove it.


  3. Remove the screw.

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  4. Slide the Left SC Cover (A) toward the rear of the product to disengage the tab.
  5. Disengage the three tabs by inserting a flathead screwdriver into the gap between the Left SC Cover (A) and the ADF Unit (B), and then remove the Left SC Cover (A).
  6. Open the Duplex Print Cover (A).
  7. Remove the two screws, then remove the Connector Cover (A).

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  8. Remove the two screws, then remove the Right Housing Assy (A) toward the rear of the product.

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  9. Remove the two screws.
    • : C.C.S-TITE-3x6-F.ZN-3C
  10. Raise the ADF Stopper (A) to lock the ADF Unit.
  11. Secure the ADF Stopper with one of the screws you removed at step 1.
    • : C.C.S-TITE-3x6-F.ZN-3C
  12. Hold the ADF/SCN Unit (A) with both hands as shown above, and open the ADF/SCN Unit (A).
  13. Open the ADF/SCN Unit (A) and extend the support stand (B) as far as it goes, then support theADF/SCN Unit (A) with the support stand.


    Caution / 注意

    Make sure that the extended support stand is fixed with the two hooks, and the two triangle marks face to each other.

    Check Point / チェックポイント

    When closing the ADF/SCN Unit, hold down the switch on the support stand and raise the ADF/SCN Unit in the direction of the arrow to disengage the two hooks, then fold the support stand.

  14. Remove the three screws, then remove the Left Housing Assy (A) toward the rear of the product.

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  15. Remove the Stacker Assy (A).


  16. Remove the Cassette Assy (A).
  17. Open the Front Cover Assy (A).
  18. While pressing the two hooks of the hinge (A), remove the Front Cover Assy (A) frontward.
  19. Remove the three screws fastening the Front Left Housing (A).

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  20. Release the hook and remove the Front Left Housing (A).
  21. Remove the Front Cover Hinge Left (B) from the Dowel on the Front Inner Housing Left (A).
  22. Remove the four screws, then remove the Front Inner Housing Center (A) frontward.

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  23. Remove the two screws fastening the Front Inner Housing Left (A).

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  24. Remove the Front Inner Housing Left (C) while releasing the place interfering (A) with the ADF/SCN Unit (A).
  25. Release the Panel FFC (B) from the two clamps (A).
  26. Remove the two screws and remove the Power Supply Unit Cover (A).
    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  27. Release the two cables from the two clamps (A).
  28. Remove the cables from the connectors (CN2 (with hooks), CN3, CN5) of the Power Supply Unit.
  29. Remove the Power Supply Unit Cable (B) from the Power Supply Unit (A) while releasing the hook.
  30. Remove the three screws and remove the Power Supply Unit (A).

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  31. At the full side, disengage the Extension Spring (A) from the hook of the frame.

    Caution / 注意
    • The CR Scale is made of SUS and very fragile. Therefore, take extreme care when handling one.
    • If you disassemble the CR Scale, exchange it for the new CR scale.
  32. Remove the CR Scale (A) from the hook of frame.
  33. At the home side, remove the CR Scale (A) from the hook of the frame.
  34. Pull out the CR Scale (B) from the slit of the CR Unit  (A).


    Assembly / 組み立て

    Follow the procedure below to install the CR Scale.

    1. At the full side, hook the CR Scale (A) on the frame.
    2. Hook the Extension Spring (A) on the frame.
    3. Route the CR Scale (B) through the slit on the CR unit (A).
    4. At the home side, hook the CR Scale (A) on the frame.
    5. Check the hook is inserted all the way.



Adjustment / 調整

After replacing this part, you need to run the menu from the service support mode.

(If you ran the Before-replacement menu before replacing the part, it will start automatically when you turn the power on.)