ASF PID excess load error (error code: 000061)
Cause
- State in which load of ASF motor exceeds expected load
- When rotated in the opposite direction to rotation direction
(There was a sudden load error, and the motor rotated in the opposite direction in reaction to it) - State in which load of motor exceeds expected load, and motor does not rotate at all
Suspected cause
- Paper jam paper remaining
- Paper path damaged and feed roller worn out
- Gears locking due to foreign object
- Locked because ASF gear train part failure
- ASF motor encoder failure
- PF motor failure
- Motor driver failure/main board failure
Troubleshooting
| Procedure | Check and measure | Yes | No |
|---|---|---|---|
| Advance check 1 | Check for foreign object or jammed paper remaining |
Go to advance check 2 | Remove the jammed paper or foreign object. |
| Advance check 2 | Check the timing of error occurrence |
Go to step 2 | Go to step 1 |
| 1 | Check the feed roller and conveyance roller. |
Go to step 2 | Replace the feed roller or replace the Rear Unit. |
2 |
Check the ASF motor operation |
Go to step 4 | Go to step 3 |
| 3 | Check the ASF gear train parts |
Replace the ASF Motor Assy. |
Remove the foreign object or replace the ASF Motor Assy. |
| 4 | Check the ASF motor operation |
Replace the main board |
Replace the ASF motor encoder |