REL PID excess load (error code: 100029)
Cause
- The drive time of the motor exceeded the set time.
- When rotated in the opposite direction to rotation direction (There was a sudden load error, and the motor rotated in the opposite direction in reaction to it)
- State in which load of motor exceeds expected load, and motor does not rotate at all
Suspected cause
Foreign object or jammed paper remaining
ADF release motor cable disconnected
Encoder FFC disconnected
ADF release motor failure
Encoder failure
ADF Board failure
Troubleshooting
Procedure |
Check and measure |
Yes |
No |
|---|---|---|---|
| 1 | Check for paper jam paper remaining and foreign object |
Go to step 2 |
Remove the jammed paper or foreign object. |
| 2 | Check the connection state of the ADF release motor cable Remove the Front ADF Cover Assy. Check that the ADF release motor cable (CN303) and encoder FFC (CN16) is not disconnect. |
Go to step 3 | Reconnect the cables. |
| 3 | Check the ADF release motor gear train parts Remove the Front ADF Cover Assy. Check the ADF release motor gear train parts, and check that there are no foreign objects. |
Replace the following parts in sequence, and check the change in status of each replaced part.
(If the trouble is not resolved, inquire at Epson Service Support department.) |
ADF release motor gear train parts. |