PF Encoder Assy

  1. Remove the three screws, then remove the Left Housing Assy (A) toward the rear of the product.

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  2. Remove the hole from the screw feet (A) and pull out the folded portion (C) of the PF Scale Protection Material (B).
  3. Release the two hooks and remove the PF Scale Protection Material (A).
  4. Remove the screw, then remove the Left PG Cam Screw Holder (A) with the screw.

    • : C.C.SCREW-3x6-F.ZN-3C
  5. Remove the screw, then remove the Anti Static Brush Plate (A).
    • : C.B.S-TITE-SCREW-3x6-F.ZN-3C
  6. Remove the E-ring (A), then remove the Spur Gear (B).
  7. Remove the FFC (B) from the connector of the PF Encoder Assy (A).
  8. Remove the screw, and remove the PF Encoder Assy (A).

    • : C.B.S-TITE-SCREW-3x6-F.ZN-3C