PF Belt Tension Stopper

  1. Remove the three screws, then remove the Left Housing Assy (A) toward the rear of the product.

    • : C.B.S-TITE-SCREW-3x8-F.ZN-3C
  2. Mark (C) the location where the PF Belt Tension Stopper (A) and the PF Pulley Holder (B) touch.
  3. Loosen the screw that secures the PF Belt Tension Stopper (A).

    • : C.B.S-TITE-P4-SCREW-3x8-F.ZN-3C
  4. Remove the PF Belt Tension Stopper (A) feet (B) from the hole in the frame.
  5. Release the hook by rotating the PF Belt Tension Stopper (B) in the direction of the arrow around the shaft (A), and remove the PF Belt Tension Stopper (B).