NOZZLE NOISE CHECK [B26]
- Start the service support mode. (Service mode startup and operating procedures)
- Select “Adjustment Main Unit: MENU” from the service support mode top menu.
Select “Nozzle Noise Check”.
Check Point / チェックポイントSelect and execute the corresponding adjustment item using either procedure below.
Selecting by entering the program number
- Select “Input B No.-Main Unit Adjust” from the Adjustment menu.
- Press the [#] button and software number key is displayed on LCD. Enter program number “26”.
- Press the [#] button.
Selecting from menu
- Select “Individual Adjustment: MENU” from the Adjustment menu.
- Select “Printing Check: MENU” from the Individual Adjustment menu.
- Select “Nozzle Noise Check” from the Printing Check menu.
- The check result is displayed on the panel. If NG, check whether the Print Head and Head FFC are assembled correctly. If there is a problem, replace the Print Head and Head FFC with new ones.