NIP SOLENOID/SENSOR [B25]

  1. Start the service support mode. (Service mode startup and operating procedures)
  2. Select “Adjustment Main Unit: MENU” from the service support mode top menu.
  3. Select “NIP Solenoid/Sensor”.

    Check Point / チェックポイント

    Select and execute the corresponding adjustment item using either procedure below.

    • Selecting by entering the program number

    1. Select “Input B No.-Main Unit Adjust” from the Adjustment menu.
    2. Press the [#] button and software number key is displayed on LCD. Enter program number “25”.
    3. Press the [#] button.
    • Selecting from menu

    1. Select “Individual Adjustment: MENU” from the Adjustment menu.
    2. Select “Mech Check MENU” from the Individual Adjustment menu.
    3. Select “NIP Solenoid/Sensor” from the Mech Check menu.
  4. Check the operation of the nip release solenoid visually and by its sound.
  5. The check result is displayed on the panel. If NG, check whether the Intermediate Release Solenoid Lever and Intermediate Release Solenoid are assembled correctly. If there is a problem, replace the Intermediate Release Solenoid Lever and Intermediate Release Solenoid with new ones.