NIP SOLENOID/SENSOR [B25]
- Start the service support mode. (Service mode startup and operating procedures)
- Select “Adjustment Main Unit: MENU” from the service support mode top menu.
Select “NIP Solenoid/Sensor”.
Check Point / チェックポイントSelect and execute the corresponding adjustment item using either procedure below.
Selecting by entering the program number
- Select “Input B No.-Main Unit Adjust” from the Adjustment menu.
- Press the [#] button and software number key is displayed on LCD. Enter program number “25”.
- Press the [#] button.
Selecting from menu
- Select “Individual Adjustment: MENU” from the Adjustment menu.
- Select “Mech Check MENU” from the Individual Adjustment menu.
- Select “NIP Solenoid/Sensor” from the Mech Check menu.
- Check the operation of the nip release solenoid visually and by its sound.
- The check result is displayed on the panel. If NG, check whether the Intermediate Release Solenoid Lever and Intermediate Release Solenoid are assembled correctly. If there is a problem, replace the Intermediate Release Solenoid Lever and Intermediate Release Solenoid with new ones.