Write Parity Error (Error code: 033007)

Cause

Communication error when reading/writing data from the CRCM

Suspected cause
  • CRCM FFC detached
  • CRCM FFC failure
  • CRCM board failure
  • Main Board failure

A: CRCM FFC

Troubleshooting
Step Confirmation and action Yes No
1

Check the CRCM FFC connection state.
Check that the FFC between the main board and CRCM board is connected correctly.

Go to step 2

Reconnect the FFC.

2

Check whether the CRCM FFC is disconnected/damaged

Check that there is no disconnection between the main board and CRCM and that the connector parts are not bent up.

Go to step 3 Replace the CRCM FFC
3

Check the operation after reinstalling the CRCM board

Reinstall the CRCM board and check whether or not the error occurs.

Does the error occur?

Replace the main board

Replace the CRCM Board