TEMP/HUM. SENSOR [B24]
Adjustment procedure
- Start the service support mode. (Service mode startup and operating procedures)
- Select “Adjustment Main Unit: MENU” from the service support mode top menu.
Select “Temp/hum. Sensor”.
Check Point / チェックポイントSelect and execute the corresponding adjustment item using either procedure below.
Selecting by entering the program number
- Select “Input B No.-Main Unit Adjust” from the Adjustment menu.
- Press the [#] button and software number key is displayed on LCD. Enter program number “24”.
- Press the [#] button.
Selecting from menu
- Select “Individual Adjustment: MENU” from the Adjustment menu.
- Select “Mech Check MENU” from the Individual Adjustment menu.
- Select “Temp/hum. Sensor” from the Mech Check menu.
Judgment
Check the output values of the temperature and humidity sensors and confirm whether or not they are normal.
Check Point / チェックポイントError judgment guide is belows.
- Broken wire:0 ºC or less is indicated
- Short:60 ºC or more is indicated
- Touch the temperature sensor and check that there is a change to the output value.
- If NG, check the connection state of the temperature and humidity sensors. If there is a problem, replace the temperature and humidity sensors with new ones.