Main-B board μSD recognition error (error code: 100094)

Cause

Occurs if the μSD on the SCN board cannot be recognized.

Suspected cause
  • μSD disconnected
  • μSD failure
  • ADF/SCN unit failure (SCN main board failure)
Troubleshooting
Step Confirmation and action Yes No
1

Check the μSD attachment state
Is the μSD attached correctly?

Go to step 2

Reattach the μSD.

2

Check the operation after reinserting the μSD
Reinstall the μSD and check whether or not the error occurs. Did the error occur?
Does the error occur?

Replace the ADF/SCN Unit

Replace the μSD.