Main-B board μSD recognition error (error code: 100094)
Cause
Occurs if the μSD on the SCN board cannot be recognized.
Suspected cause
- μSD disconnected
- μSD failure
- ADF/SCN unit failure (SCN main board failure)
Troubleshooting
| Step | Check and measure | Yes | No |
|---|---|---|---|
| 1 | Check the μSD attachment state |
Go to step 2 |
Reattach the μSD. |
| 2 | Check the operation after reinserting the μSD |
Replace the ADF/SCN Unit |
Replace the μSD. |