APG target position not reached error (error code: 034011)

Cause
  • Even if the APG reset operation is performed, it occurs when the home can not be detected and the position becomes unknown

Suspected cause
  • APG phase sensor failure
  • Main Board Assy failure
Troubleshooting
Step Check and measure Yes No
1

Check the APG phase sensor state
Perform the ”Individual action check (30108 APG Operation Check)”, and check the sensor state. Is the sensor normal?

Replace the Main Board.

APG phase sensor replacement