Addition communication error 3 (Error code:032153)
Cause
- Occurs during communication data abnormality due to noise etc., or when the communication has not been established between the printer and the optional cassettes.
- Occurs when changing the number of stages of optional cassettes while the power is on.
Suspected cause
- Optional cassette connection part failure
- Optional Paper Cassette Main Board failure
- Main Board Assy failure
Troubleshooting
| Step | Check and measure | Yes | No |
|---|---|---|---|
| 1 | Check if the error occur with turning the printer off and on. |
Go to step 2 | End |
| 2 | Check the operation after reinstalling the optional cassette |
If the error did not occur, go to step 3. | If the error occurred, replace the Main Board Assy. |
| 3 | Check the operation after reinstalling the Connection part of optional cassette |
Replace the additional board unit |
End |